myspace hits counter

APC S20 - v 7.0.0

Extra Vegetables' Control4 driver for the APC (American Power Conversion) range of UPS enables a Control4 system both to control the operation of the UPS and to receive feedback from it.

This is an invaluable tool on any customer's site as it allows the Control4 system to monitor the health of the power at the property and to react accordingly. Should a problem occur with the power the dealer can be informed of the problem and, if an IP power switch, is installed it is possible to provide a controlled shut down and power save sequence for the property. Dealers can also remotely interrogate the UPS to analyze the current power conditions through Remote Director.

This is the driver for the APC S20 AV Power Conditioner with battery backup. This driver provides all of the functions of the SmartUPS driver together with the ability to switch any of the four outlet banks on the rear of the UPS. 

Also available as part of the Monitoring Suite with the network monitoring, rebooting and ping drivers.


Supported Control4 operating systems

Compatible with Control4 OS 2.x and above ONLY


Control4 Processor Requirements

HC800                     
HC1000
HC250 can be used on smaller systems.  Please check Control4's recommended processor requirements for your specific project.


Limitations

Supported Features 
Not all features are supported on all UPS. This really only affects the Internal Temperature feature.


Further information
The Extra Vegetables Control4 driver for SmartUPS range UPS from APC implements the following features:

Reliable two-way serial control.
The UPS is connected to the Control4 system via the special serial cable you will find included with your UPS. Don't throw it away as it is special - no other cable will work!

Allows Basic Control of the UPS .
You can initialize the UPS and you can also cause it to undertake a self test.

Can interrogate the UPS for status
Both directly in Composer and through dealer programming you can initiate of query the following: ◦Display Time of Shutdown
◦Display Time of Line Restored
◦Display Time of Line Failure
◦Display cause of transfer
◦Display Internal Temperature
◦Display Power Load
◦Display Battery Level
◦Display Minimum Input Line Voltage
◦Display Maximum Input Line Voltage
◦Display Input Voltage
◦Display Output Voltage

Receive notifications from the UPS.
The UPS will send Control4 notifications on the following events:
◦UPS Line Fail (i.e. switching to battery) ◦UPS Line Restored (i.e. returning to mains power)
◦UPS Die (out of battery and shutting down) These events can then be used in dealer programming to perform a controlled shutdown of the system (using and IP power switch) or to send your customer or yourselves and email warning of the power condition.

Switch any of the four power outlet banks on the S20
You can use Control4 to switch any of the outlet banks on the APC S20 Power Conditioner with battery backup. This allows you to remotely reboot any device connected to these outlets by using the 'Remote Director' function in Composer. You can also use this functionality to switch off devices connected to these outlets to conserve power in the case of the system switching to battery power. Please note the APC S20 is a 110v device and is not available in Europe.


Disclaimer

This driver is an independent commercial release by Extra Vegetables Ltd.  It is not authorized or supported either by Control4 or APC.  Extra Vegetables fully support the driver through its authorized dealer network.

Click to enlarge

 

Features

  • Reliable two-way serial control.
  • Enables basic control of the UPS such as performing a self test.
  • Can interrogate UPS for status such as input or output voltages.
  • Receive notifications from the UPS on transfer to battery power and restoration of mains power.
  • Switch any of the four power outlet banks on the S20